logo_apricot Designs that make sense  

PP-384-M Series Personal Pipettor™

The PP-384-M series offers 384 channel high performance pipetting that is ideal for low volume multichannel microplate pipetting and for serial dilution applications. The microprocessor-controlled pipetting mechanism provides accurate and precise pipetting of microliter volumes of samples into 96, 384 or 1536-well microplates. The high-speed pipetting system provides short processing times by delivering liquids through up to 384 channels simultaneously with precise volume control.

pp-384-m
NEW
NEW EZ-Load heads allow loading and unloading of dispoable tips without tools.

The Personal Pipettor (PP) is a popular series of affordable liquid handling systems with the versatility and reliability required for today’s demanding laboratory environment. The PP series offers the majority of automated features that many laboratories need at a reasonable price, making it possible for each technician to truly have their own “personal” pipettor.

The PP-384-M series offers 384 channel high performance pipetting that is ideal for low volume
multichannel microplate pipetting and for serial dilution applications. The microprocessor controlled
pipetting mechanism provides accurate and precise pipetting of microliter volumes of
samples into 96, 384 or 1536-well microplates. The high-speed pipetting system provides short
processing times by delivering liquids through up to 384 channels simultaneously with precise volume
control.

Features

  • Flexible design for liquid transfers and pipetting operations for 96, 384 and 1536-well microplates and
    can also be used for serial dilutions by row or column.
  • Uses the unique easy-change head system from Apricot Designs, allowing the user to build a diverse head
    library with a reasonable investment. The heads are interchangeable with other Apricot pipettors.
  • 5-position deck with wash station allows walkaway reformatting of 4x96 to 1x384 or 1x384 to 4x96.
  • Intuitive graphical user interface via serial interface control to laptop/PC.
  • Small footprint conserves bench space and fits easily into suitably-sized hoods.

Options

  • Fixed tip heads with 8, 12, 16, 24, 96 and 384 channels.
  • Disposable tip heads with 8, 12, 16, 24, 96 or 384 channels for Apricot ESP tips, Apricot 550 tips, or Biomek® FX tips.
  • Tip washing system with recirculating pump.
  • Optional Bluetooth wireless control for serial connection to computer.

Applications

  • Plate replication
  • Plate reformatting
  • Reagent addition
  • Compound addition
  • Serial dilution (by row or column)

Automation

The open deck design makes it easy to use robotics to supply labware to the PP series. It can be integrated
as part of an automation workcell by combining it with laboratory automation software and robotics from
Apricot’s sister company Biosero, Inc.

Specifications

  • Dispensing Precision

<2% CV at 1 ul (96) <2.8% CV at 1 ul (384)

  • Dispensing Accuracy

+/- 1% at 1 ul (96) +/- 1.25% at 1 ul (384)

  • Resolution

0.1 ul 384/96 offset)

  • Pipette Volume

0.5 - 125 ul (384)

  • Dimensions
28”W x 19”D x 23.5”H 711W x 495D x 597H mm
Operating Width for stage 39.5" 1003 mm
  • Weight

Approx. 98 lbs (45 kg)

  • Power

100 to 240 VAC, 50/60 HZ

  • Operating Temperature

50 - 100 ºF

  • Warranty

12-month extensive manufacturer warranty

Extended 12-month warranty and Annual Service plan are also available. Contact factory or authorized dealers for detail

Accessories

Fixed Tip Heads. All fixed tip heads feature stainless steel tips with PTFE coating on inside and outside and have an internal diameter of 0.032 inch. Custom heads for unique or new applications are also available.

Part Number

Picture (click to enlarge) Number of channels Maximum volume per tip (ul) Plate compatibility Serial Dilution
125-A-01-023
(Requires Wash Manifold 125-A-09-384)
pipettor head
384
125
384, 1536*
None
125-A-02-023-25U
(Requires Wash Manifold 125-A-09-384)
pipettor head
384
25
384, 1536*
None
125-A-01-023-SC-M
(Requires Wash Manifold 125-A-09-384-SC)
pipettor head
16
125
384, 1536*
Columns only
125-A-01-023-SR
(Requires Wash Manifold 125-A-09-384-SR)
pipettor head
24
125
384, 1536*
Rows only
125-A-03-023
(Requires Wash Manifold 125-A-09-096)
pipettor head
96 (offset)
125
96,384*
None
125-A-04-023-25U
(Requires Wash Manifold 125-A-09-096)
pipettor head
96 (offset)
25
96,384*
None
125-A-03-023-SC-M
(Requires Wash Manifold 125-A-09-096-SC)
pipettor head
8 (offset)
125
96,384*
Columns only
125-A-03-023-SR
(Requires Wash Manifold 125-A-09-096-SR)
pipettor head
12 (offset)
125
96,384*
Rows only

* The PP-384-M will automatically index as to position the tips for these plates .

Disposable Tip Heads. Custom heads for unique or new applications are also available.

Part Number

Picture (click to enlarge)

Compatible Tips

Number of channels Maximum volume per tip (ul) Plate compatibility Serial Dilution
384-A-01-EZL
(EZ-LOAD)

pipettor head
ESP 50 & 125 ul
384
125
384, 1536*
Rows or Columns **
384-A-01-EZL-096
(EZ-LOAD)
pipettor head
ESP 50 & 125 ul
96 (offset)
125
384, 1536*
Rows or Columns **
TPS384-A-01-ESP
(Requires 125-A-11 Tip Loader / Ejector)
pipettor head
ESP 50 & 125 ul
384
125
384, 1536*
Rows or Columns **
125-A-05-55N
(Requires Tip Loader / Ejector 550-A-45N, Tip Holder 550-A-04-46N and Lube Box 550-A-08
pipettor head
Apricot 550
96 (offset)
125
96, 384*
Rows or Columns **
125-A-06-20N
(Requires Tip Loader / Ejector 550-A-45N and Tip Holder 550-A-04-20N)
pipettor head
Biomek 25, 50 & 250 ul
96 (offset)
125
96, 384*
Rows or Columns **
TPS384-A-01-096ESP
(Requires 125-A-11 Tip Loader / Ejector
pipettor head
ESP 50 & 125 ul
96 (offset)
125
96, 384*
Rows or Columns **

* The PP-384-M will automatically index as to position the tips for these plates .
** The operator can manually load one row or one column of tips for serial dilution operations.

Accessories.

Part Number

Picture (click to enlarge) Description Compatible head
125-A-09-384
Wash Manifold
wash manifold
Wash manifold fits over top of 384 channel fixed tip head. The head is washed by connecting to a faucet.
125-A-01-023, 125-A-02-023-25U, 125-A-05-55-41F
125-A-09-384-SC
Wash Manifold
wash manifold
Wash manifold fits over top of 16 channel fixed tip head. The head is washed by connecting to a faucet.
125-A-01-023-SC-M
125-A-09-384-SR
Wash Manifold
wash manifold
Wash manifold fits over top of 24 channel fixed tip head. The head is washed by connecting to a faucet.
125-A-01-023-SR
125-A-09-096
Wash Manifold
wash manifold
Wash manifold fits over top of 96 channel fixed tip head. The head is washed by connecting to a faucet. 125-A-03-023, 125-A-04-023-25U
125-A-09-096-SC
Wash Manifold
wash manifold
Wash manifold fits over top of 8 channel fixed tip head. The head is washed by connecting to a faucet. 125-A-03-023-SC-M
125-A-09-096-SR
Wash Manifold
wash manifold
Wash manifold fits over top of 12 channel fixed tip head. The head is washed by connecting to a faucet. 125-A-03-023-SR
125-A-11
Tip Loader/Ejector
tip loader
Tool for manually loading loading and ejecting tips.
TPS384-A-01-ESP, TPS384-A-01-096ESP

550-A-45N
Tip Loader/Ejector
tip loader
Tool for manually loading loading and ejecting tips. 125-A-05-55-41DN, 125-A-05-55N, 125-A-06-20N
550-A-04-46N
Tip Supporting Holder
tip holder
Supports rack of Apricot 550 tips for the 550-A-45N Tip Loader/Ejector.
125-A-05-55-41DN, 125-A-05-55N
550-A-04-20N
Tip Box Spacer
tip holder
Supports Biomek tip rack for the 550-A-45N Tip Loader/Ejector.
125-A-06-20N
550-A-08
Lube Box
lube box
Pipetting head lubrication box for reliable seal of mandrel o-rings.
125-A-05-55-41DN
384-A-11
Tip Washing System
wash system
Tip washing system controlled by pipettor software interface.
All
550-A-16
Cooling Plate, horizontal ports
cooling plate
Installed on the deck; Requires recirculating bath.
All
550-A-16P
Cooling Plate, perpendicular ports
cooling plate
Installed on the deck; Requires recirculating bath.
All
096-A-027
Bluetooth Wireless
Image coming soon
Optional Bluetooth Wireless USB and Serial communications allow remote operation wirelessly.
All